The heating element is a simple radiant heating unit designed to prevent contaminants and waste water from gelling when stored in the purifier in cold environments.
Installation
1. Apply Teflon tape (or other approved thread sealant) to the threads of the heater.
2. Insert heater into the heater coupling and tighten into the body of the purifier.
3. Connect (1) lead to negative side of a 120 VAC switch controlled circuit (using appropriate wire connectors).
4. Connect (1) lead to the positive side of the 120 VAC switch controlled circuit (again using the appropriate wire connectors).
240V Heating Unit #FP-HTR-240
Installation
12/24V Heating Unit #FP-HTR-12/24
Installation
Apply Teflon tape (or other approved thread sealant) to the threads of the heater. Insert heater into the heater coupling and tighten into the body of the purifier.
WIRING 12 VDC HEATER:
Connect the two black leads together and attach to the negative side of a switch controlled fused circuit (using appropriate wire connectors).
Connect the common lead (white with black tr positive side of the switch controlled fused circuit (again using the appropriate wire connectors).
WIRING 24 VDC HEATER:
Remove excess wire from the common lead (white with black tracer) leaving 1 to 2 inches of wire. Cap common lead with appropriate wire cap and crimp. Connect the two black leads to the 24-volt switched fused power supply (using the appropriate connectors).